TC10 – Cold rooms up to 12 m3

TC 10 kjøleaggregat bruker opp mot 50% mindre strøm enn tradisjonelle kjølemaskiner.

TC-aggregatene er en oppgradering og en erstatter av våre TL-aggregater. Oppgraderingen på TC er i hovedsak reduksjon av strømforbruk og bytte til miljøvennlig kjølegassen R600a. Modellen passer godt ved utskifting av eksisterende TL kjøleaggregater, selvbygde kjøleromeller Thermocold sine element kjølerom.

SKU: 10150 Category:

Description

Thermocold TC 10 cooling unit for use in cold rooms up to 12000 liters

The model is suitable for replacing existing TL and TC cooling units, self-built cold rooms or Thermocold’s element cold rooms.

The Thermocold cooling unit is mounted from the inside of the cold room and through the cold room wall. This provides much greater flexibility with regard to mounting solutions.

See the installation guide and download tab for different options.

Light opening in wall: 440x740mm

Winter operating kits should be installed at colder temperatures of + 16 ° C

 

Why choose us Thermocold

  • Low on power consumption
  • Dust filter, easy maintenance
  • Low noise level and low vibration
  • 5 year warranty
  • Norwegian produced quality product
  • Many mounting options, ventilation grille or plastic cover on the back
  • Eco-friendly cooling gas
  • Digital display for setting temperature
  • Best on service

The cooling units are ranked according to a cold room made up of our cold room elements with Thermocold cold room door.
Volume is given in liters, with up to maximum size.

Cooling rooms built of elements: Cooling rooms made of elements have better insulation capacity than one cold room built in wood. Our 5cm thick cold storage meter equals 10cm with insulation. Here one does not have to think about how the room should be built up. Thermocold’s cold room elements are quick to assemble and have a surface that prevents bacteria from multiplying.

Cooling rooms built in wood: Make sure the room is built according to NS (Norwegian standard) or better. NS sets the minimum standard for self-built cold rooms, which describes the correct construction of cold rooms built in wood. Requirements for insulation are laid in floors, walls and ceilings. See more information about building here: Build your own cold room

Ambient temperature indicates the application area of ​​the cooling unit / cold room. At lower temperatures that can occur in e.g. cold basements, garages etc. you need winter control for the unit to have optimal operation or not damage.

NB! Various refrigeration doors, worn door gaskets, glass panels or glass doors in the room will require different calculation of performance, contact us or a dealer to evaluate the performance of the refrigerator.

 

 

Assembly Options

There are several assembly alternatives, find out which option is best for you and follow the installation instructions carefully.

Alternative 1
Self-built cold room with plastic cover.

Alternativ 2
Self-built cold room with fixed ventilation louvres on the foor and ceiling.

Alternative 3
Self-built cold room with vertical fixed ventilation louvres mounted sideways.

Element Cold Room with Fixed Ventilation Louvres / Grates

Alternative 4
Element cold room with fixed ventilation grates.

Alternativ 5
Element cold room, free-standing.

Alternative 5
Element cold room with fixed ventilation grates.

TC10 – Kjølerom opptil 12 m3 
Utvendig mål:B475-D230-H787 mm
Lysåpning i vegg: B440-H740 mm
Kjølemedium: R600A 106g
Spenning: 220-240V AC 50Hz
Strømtrekk: 1,67 A 220-2240V 50Hz
Termostat innstilling:3-20°C
Omgivelsestemperatur:16-27°C
Nettovekt: 24 kg
Støvfilter: Ja
Fordamping av kondensvann:Ja